  • Insulation PVC / XLPE
  • Tensile Strength 10 N/mm for insulation
  • Install Type Indoor/Outdoor, Direct Buried, Conduit
  • Core Number 2, 4, 8, 12, 24, up to 61
  • Core Material Copper
  • Number of Conductor 2 to 61
  • Conductor Type Stranded
  • Click to View more
X

Instrumentation Cables Price And Quantity

  • 4-1000 INR/Meter
  • 100 , , Meter
  • Pairs, Triads, Quads (as per requirement)
  • Individually and/or collectively shielded
  • >200 M/km at 20C
  • 100% coverage with drain wire
  • Max 250 pF/m (core to core)
  • 0.9 mm to 2.8 mm (as per spec.)
  • Standard coil, Wooden drum, or customer required packing
  • Available with FR/FRLS/LSZH jackets
  • 12 x outer diameter

Instrumentation Cables Product Specifications

  • PVC / XLPE
  • 10 N/mm for insulation
  • Copper, PVC, XLPE, Mylar, Steel (for armored)
  • 100 meters (Standard), Custom lengths available
  • 2, 4, 8, 12, 24, up to 61
  • Indoor/Outdoor, Direct Buried, Conduit
  • Copper
  • 2 to 61
  • PVC, FRLS PVC, LSZH, PE
  • Stranded
  • PVC / XLPE
  • Annealed Tinned Copper
  • 2.0 kV AC for 1 minute
  • Instrumentation Cable
  • 300/500V
  • Varies per configuration
  • Varies as per specification & length
  • Round
  • 0.5 sq.mm, 0.75 sq.mm, 1.0 sq.mm, 1.5 sq.mm (custom sizes available)
  • Customizable, Default Black
  • Black, Grey
  • Aluminium Mylar tape with tinned copper drain wire
  • Pairs, Triads, Quads (as per requirement)
  • Individually and/or collectively shielded
  • >200 M/km at 20C
  • 100% coverage with drain wire
  • Max 250 pF/m (core to core)
  • 0.9 mm to 2.8 mm (as per spec.)
  • Standard coil, Wooden drum, or customer required packing
  • Available with FR/FRLS/LSZH jackets
  • 12 x outer diameter

Instrumentation Cables Trade Information

  • 50000 , , Meter Per Month
  • 2 Week
  • Yes

Product Description

Instrumentation Cables

We are engaged in manufacturing, exporting and supplying high quality range of Instrumentation Cables. These cables are widely acclaimed for their remarkable features like high performance and optimum quality. The offered cables are used for various applications such as to connect instruments, computers, temperature sensors, process control systems and data transmission. Further, we offer a wide range of Instrumentation Cables in various different thicknesses and specifications at very cost effective prices.


  



Superior Interference Protection

Our instrumentation cables incorporate individually or collectively shielded configurations with aluminium mylar tape and a tinned copper drain wire, achieving over 100% screen coverage. This design ensures minimal signal degradation and maximum EMI protection, making them ideal for critical measurement and control circuits in industrial settings. With capacitance limited to 250 pF/m (core to core), signal clarity is preserved across every installation.


Customizable and Versatile Solutions

With options for twisted pairs, triads, or quads, our cables can be tailored to specific instrumentation requirements. Choose conductor counts from 2 up to 61, and select insulation and jacket materials (PVC, FRLS, LSZH, PE) to align with project specifications. Multiple sizes, sheath thicknesses, and packaging choices further enhance their application flexibility for any environment.


Engineered for Safety and Durability

Built to withstand challenging conditions, these cables feature high insulation resistance (>200 M/km), low dielectric strength (2.0 kV AC), and minimum bending radius (12x diameter). Fire-resistant jackets, robust construction, and optional armoring offer consistent performance in harsh environmentsbe it direct burial, conduit, indoor, or outdoor setups.

FAQs of Instrumentation Cables:


Q: How are instrumentation cables with twisting and shielding constructed?

A: Instrumentation cables are designed with twisted pairs, triads, or quads to reduce cross-talk and external interference. Each group of conductors may be shielded individually and/or collectively using aluminium mylar tape and a tinned copper drain wire, ensuring 100% coverage for reliable signal transmission.

Q: What are the typical applications for these instrumentation cables?

A: These cables are widely used in process control, signal transmission, measurement systems, and communication in industrial settings. Their robust construction suits installations indoors or outdoors, in conduits, or direct burial, offering dependable performance in harsh environments.

Q: When should I opt for fire-resistant or LSZH jacket options?

A: Fire-resistant (FR), Flame-Retardant Low Smoke (FRLS), and Low Smoke Zero Halogen (LSZH) jackets are recommended for environments where enhanced fire safety and reduced toxic emissions are needed, such as in public buildings, tunnels, or high-population areas.

Q: Where can these instrumentation cables be installed?

A: These cables can be installed in a variety of environments, including control rooms, outdoor locations, direct buried applications, or through conduits. They are suitable for both manufacturer plants and supplier projects across India and beyond.

Q: How does the cables insulation resistance benefit system reliability?

A: With insulation resistance greater than 200 M/km at 20C, these cables minimize leakage currents and help maintain optimal signal integrity, which is crucial for accurate data transmission and long-term system reliability in sensitive electronic equipment.

Q: What customization options are available for length, color, and configuration?

A: We offer standard lengths of 100 meters as well as custom lengths upon request. Jacket colors like black and grey are standard, but other shades can be customized. The number of conductors, size, and connector color are fully configurable based on project requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Rubber Cables' category



Back to top